ASL evaluated the suitability of the ex-situ temperature sensors for use as potential temperature indicators in cases of fire and arson investigations. The sensors, in the shape of small pressed pellets, were placed inside test structures that were subsequently set on fire. The results indicate good agreement between the optical sensor readings and traditional thermocouple-based reference measurements.

References:

1. Benjamin R. Anderson, Natalie Gese, Ray Gunawidjaja, and Hergen Eilers, “Burn Chamber Test of Ex-situ Thermal Impulse Sensors,” Appl. Spectroscopy 74 (5), 515-524 (2020). doi: 10.1177/0003702819884131.

2. Benjamin R. Anderson, Natalie Gese, Ray Gunawidjaja, and Hergen Eilers, “Nanoscale Ex- Situ Thermal Impulse Sensors for Structural Fire Forensics,” Appl. Spectroscopy, 72(9), 1310-1321 (2018), DOI: 10.1177/0003702817734292